locks: record capacity and clear semantics
This commit is contained in:
+12
-12
@@ -1,9 +1,10 @@
|
||||
# Door Locks & Codes
|
||||
|
||||
<overview>
|
||||
Two Z-Wave (zwave_js) keypad locks: `lock.lodge_front_door_lock` (node 3) and
|
||||
`lock.bunkhouse_frontdoor_lock`. 8 shared code slots, managed from the
|
||||
"Lock Management" Lovelace view via helpers:
|
||||
Two Kwikset HC620 Z-Wave (zwave_js) keypad locks:
|
||||
`lock.lodge_front_door_lock` (node 3) and `lock.bunkhouse_frontdoor_lock`
|
||||
(node 8). Each supports user-code slots 1–250; the automation and "Lock
|
||||
Management" Lovelace view manage shared logical slots 1–8 via helpers:
|
||||
`input_text.lock_slotN_user`, `input_text.lock_slotN_code`,
|
||||
`input_boolean.lock_slotN_lodge_enabled`, and
|
||||
`input_boolean.lock_slotN_bunkhouse_enabled` (N = 1–8).
|
||||
@@ -13,12 +14,11 @@ hidden from the dashboard.
|
||||
</overview>
|
||||
|
||||
<sync>
|
||||
All code writes go through `script.lock_sync_slot` (fields: `slot` 1–8), the
|
||||
single source of truth. Per slot and door it resolves the code (slot's own code
|
||||
if that door's toggle is on, else the slot-1 family code), refuses an invalid
|
||||
effective code for only that door with a door-specific notification, then does
|
||||
a UserCode CC `get` followed by `zwave_js.set_lock_usercode`. Every Z-Wave call
|
||||
uses `continue_on_error`, so one door never blocks the other.
|
||||
All code changes go through `script.lock_sync_slot` (fields: `slot` 1–8), the
|
||||
single source of truth. Per slot and door it refreshes the User Code CC cache,
|
||||
then writes the validated slot code when enabled or calls
|
||||
`zwave_js.clear_lock_usercode` when disabled. Every Z-Wave call uses
|
||||
`continue_on_error`, so one door never blocks the other.
|
||||
|
||||
- `script.lock_sync_all_codes` — warns (persistent + `notify.mobile_app_donavan_s_iphone_16_pro`)
|
||||
if a lock's `*_node_status` sensor isn't alive/asleep, then runs
|
||||
@@ -29,9 +29,9 @@ uses `continue_on_error`, so one door never blocks the other.
|
||||
- `automation.lock_codes_full_sync_self_heal` — full sync daily 04:00 and
|
||||
10 min after HA start, so transient failures heal within a day.
|
||||
|
||||
Each disabled door slot is overwritten with the family code, so the family code
|
||||
exists in multiple slots. Slot 1's toggles are no-ops because its fallback is
|
||||
its own family code.
|
||||
An HC620 clear is confirmed by a refreshed `in_use: false` readback. Do not
|
||||
overwrite disabled slots with the family PIN: the lock rejects a duplicate PIN
|
||||
without changing the slot even when the service call returns successfully.
|
||||
</sync>
|
||||
|
||||